Add to Cart
IFM Photoelectric distance sensor O1D100 O1DLF3KG/IO-LINK
Okay, let's take a look at the IFM Photoelectric Distance Sensor O1D100 O1DLF3KG/IO-LINK:
1. Product Name:
- IFM Photoelectric Distance Sensor
2. Model Number:
- O1D100 O1DLF3KG/IO-LINK
3. Description:
- This is a photoelectric distance sensor from IFM Electronics that is designed for non-contact measurement and detection of object distance.
- It features an IO-LINK interface for advanced communication and configuration capabilities.
4. Key Features:
- Measurement range of 20 to 100 cm (7.9 to 39.4 inches)
- Accuracy of ±1 mm (0.039 inches)
- Visible red light LED for easy alignment
- IO-LINK interface for enhanced functionality
- Compact, IP67-rated housing for industrial environments
5. Applications:
- The IFM Photoelectric Distance Sensor O1D100 is suitable for a variety of industrial applications, including:
- Position and distance monitoring
- Object detection and counting
- Fill level monitoring
- Presence/absence detection
- Conveyor and automation systems
6. Connectivity:
- The sensor features a 4-wire, M12 connector for electrical connection.
- It can be easily integrated into industrial control systems and PLC (Programmable Logic Controller) environments via the IO-LINK interface.
7. Capabilities:
- Measurement range of 20 to 100 cm (7.9 to 39.4 inches)
- Analog output signal (4-20 mA or 0-10 V)
- Programmable switching output
- IO-LINK communication interface
8. Compatibility:
- The O1D100 O1DLF3KG/IO-LINK photoelectric distance sensor is designed to be compatible with a wide range of industrial automation systems and control equipment.
- It can be easily integrated into various IO-LINK-enabled control networks and architectures.
The key features of this photoelectric distance sensor are the wide measurement range, the high accuracy, and the IO-LINK interface. The IO-LINK communication allows for advanced configuration, diagnostics, and integration capabilities, making it a versatile solution for industrial automation and control applications.
The compact, IP67-rated housing ensures the sensor can withstand the demanding environments often found in industrial settings.
The analog output signal and programmable switching output provide flexibility in integrating the sensor into control systems and automating distance-related tasks.
Overall, the IFM Photoelectric Distance Sensor O1D100 O1DLF3KG/IO-LINK is a reliable and feature-rich solution for non-contact distance measurement and object detection in a variety of industrial applications.
Please let me know if you have any other questions!
Product characteristics
Laser protection class | 2 |
Housing | rectangular |
Electrical data
Operating voltage [V] | 18...30 DC; ("supply class 2" to cULus) |
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Typ. lifetime [h] | 50000 |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. current load per output [mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (IEC 61131-2) |
Max. load [Ω] | 250 |
Analogue voltage output [V] | 0...10; (IEC 61131-2) |
Min. load resistance [Ω] | 5000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone
Max. light spot width [mm] | 15 |
Max. light spot height [mm] | 15 |
Light spot dimensions refer to | 10 m |
Background suppression [m] | 0...19 |
Measuring/setting range
Measuring range [m] | 0.2...10; (white paper 200 x 200 mm 90% remission) |
Sampling rate [Hz] | 1...50 |
Interfaces
Communication interface | IO-Link | ||||
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 | ||||
Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis | ||||
SIO mode | yes | ||||
Required master port type | A | ||||
Process data analogue | 2 | ||||
Process data binary | 3 | ||||
Min. process cycle time [ms] | 6 | ||||
Supported DeviceIDs |
|
Operating conditions
Ambient temperature [°C] | -10...60 |
Protection | IP 67 |