Add to Cart
IFM Pressure switch with IO-Link PV8000 PV-400-SEG14-UFRVG/US/ /
Okay, let's review the details for the IFM Pressure switch with IO-Link PV8000 PV-400-SEG14-UFRVG/US/:
1. Product Name:
- IFM Pressure switch with IO-Link PV8000 PV-400-SEG14-UFRVG/US/
2. Product Description:
- This is an IFM PV8000 series pressure switch with the following specifications:
- Model: PV-400-SEG14-UFRVG/US/
- Device type: Pressure switch with IO-Link communication
3. Key Features:
- Pressure monitoring and switching
- IO-Link communication interface
- Configurable switching points and hysteresis
- Compact and robust design
- Stainless steel housing
4. Technical Specifications:
- Measuring range: 0 to 400 bar (0 to 5,800 psi)
- Switching output: PNP, NO/NC configurable
- Electrical connection: M12 connector
- Process connection: G1/4 male
- Ambient temperature: -25 to 80°C (-13 to 176°F)
- Ingress protection: IP67
- Housing material: Stainless steel
5. Applications:
- The IFM PV8000 pressure switch with IO-Link is suitable for a variety of industrial applications, such as:
- Process control and monitoring
- Hydraulic and pneumatic systems
- Compressor and pump monitoring
- General pressure measurement and switching
6. Installation and Configuration:
- The pressure switch can be installed using the G1/4 process connection.
- Electrical connection is made through the M12 connector.
- Configuration and setup can be done via the IO-Link interface, allowing for easy integration and customization.
7. Certifications and Approvals:
- The IFM PV8000 pressure switch is generally designed to meet relevant industrial standards and regulations, but the exact certifications may vary based on the specific model and region of use.
Please note that the full model number, PV-400-SEG14-UFRVG/US/, may indicate that there are additional options or variations available for this pressure switch series. The specific details would depend on the complete model number selected.
If you have any other questions or need more information, please let me know.
Product characteristics
Number of inputs and outputs | Number of digital outputs: 2 | |||
Measuring range |
| |||
Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Application
Measuring element | metallic thin film cell | |||
Application | for industrial applications | |||
Media | liquids and gases | |||
Medium temperature [°C] | -40...90 | |||
Min. bursting pressure |
| |||
Pressure rating |
| |||
Note on pressure rating |
| |||
Vacuum resistance [mbar] | -1000 | |||
Type of pressure | relative pressure |
Electrical data
Operating voltage [V] | 18...30 DC |
Current consumption [mA] | < 15 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 0.3 |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
Total number of outputs | 2 |
Output signal | switching signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | < 130 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range
Measuring range |
| ||||||||||||
Set point SP |
| ||||||||||||
Reset point rP |
| ||||||||||||
In steps of |
| ||||||||||||
Factory setting |
|
Temperature monitoring
Measuring range |
| ||
Set point SP |
| ||
Reset point rP |
| ||
In steps of |
|
Accuracy / deviations
Switch point accuracy [% of the span] | < ± 0,5 (nach DIN EN 61298-2) |
Repeatability [% of the span] | < ± 0,05; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] | < ± 0,1 (BFSL) / < ± 0,2 (LS) |
Hysteresis deviation [% of the span] | < ± 0,2 |
Long-term stability [% of the span] | < ± 0,1; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Temperature coefficient span [% of the span / 10 K] | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Temperature monitoring
Accuracy [K] | ± 2 K + (0.1 x (ambient temperature - medium temperature)) |
Notes on the accuracy / deviation | temperature range -10 to 80 °C |