Add to Cart
SIEMENS 6ES7514-2SN03-0AB0 CARD REQUIRED, BUSADAPTER REQUIRED FOR 1ST INTERFACE **** APPROVALS AND CERTIFICATES ACCORDIN
Okay, got it. The details you provided are for the SIEMENS 6ES7514-2SN03-0AB0 SIMATIC S7-1500 CPU module:
Product Description:
- The 6ES7514-2SN03-0AB0 is a SIMATIC S7-1500 CPU module.
- It requires a SIMATIC memory card for program storage and additional functionality.
- A busadapter is required for the module's 1st interface.
Key Features:
- SIMATIC S7-1500 CPU module with specific processing capabilities.
- Requires a SIMATIC memory card for program storage, firmware updates, and other advanced features.
- Supports the use of a busadapter for the module's 1st communication interface.
Connectivity:
- The module has at least 1 communication interface (1st interface) that requires a busadapter for connectivity.
- The busadapter enables the use of various communication protocols and fieldbus systems, such as PROFINET, PROFIBUS, or other industrial Ethernet standards.
SIMATIC Memory Card:
- The 6ES7514-2SN03-0AB0 module requires a SIMATIC memory card for program storage, firmware updates, and additional functionality.
- The memory card provides the necessary storage capacity and enables advanced features of the CPU module.
Busadapter:
- A busadapter is required for the module's 1st communication interface.
- The busadapter allows the CPU module to connect to and communicate over different industrial communication networks and fieldbuses.
Approvals and Certifications:
- As a SIMATIC S7-1500 CPU module, the 6ES7514-2SN03-0AB0 likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- IEC 61784-2 (PROFINET)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals (e.g., DNV GL, ABS, LR, etc.)
- Any other relevant industry-specific certifications and standards required for the intended application and geography.
Please let me know if I have accurately summarized the key details of the SIEMENS 6ES7514-2SN03-0AB0 SIMATIC S7-1500 CPU module, including the required approvals and certifications.
General information | ||
Product type designation | CPU 1514SP F-2 PN | |
HW functional status | FS01 | |
Firmware version | V3.0 | |
● FW update possible | Yes | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
● Module swapping during operation (hot swapping) | Yes; Multi-hot swapping | |
● Isochronous mode | Yes; only with PROFINET; with minimum OB 6x cycle of 375 µs | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | V18 (FW V3.0) | |
Configuration control | ||
via dataset | Yes | |
Control elements | ||
Mode selector switch | 1 | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 10 ms | |
Input current | ||
Current consumption (rated value) | 0.51 A | |
Current consumption, max. | 0.7 A | |
Inrush current, max. | 1.34 A; Rated value | |
I²t | 0.3 A²·s | |
Power | ||
Infeed power to the backplane bus | 8.05 W | |
Power loss | ||
Power loss, typ. | 3.5 W | |
Memory | ||
Number of slots for SIMATIC memory card | 1 | |
SIMATIC memory card required | Yes | |
Work memory | ||
● integrated (for program) | 900 kbyte | |
● integrated (for data) | 3.5 Mbyte | |
Load memory | ||
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
Backup | ||
● maintenance-free | Yes | |
CPU processing times | ||
for bit operations, typ. | 6 ns | |
for word operations, typ. | 7 ns | |
for fixed point arithmetic, typ. | 9 ns | |
for floating point arithmetic, typ. | 37 ns | |
CPU-blocks | ||
Number of elements (total) | 8 000; Blocks (OB, FB, FC, DB) and UDTs | |
DB | ||
● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
● Size, max. | 3.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
FB | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 900 kbyte | |
FC | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 900 kbyte | |
OB | ||
● Size, max. | 900 kbyte | |
● Number of free cycle OBs | 100 | |
● Number of time alarm OBs | 20 | |
● Number of delay alarm OBs | 20 | |
● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 250 µs | |
● Number of process alarm OBs | 50 | |
● Number of DPV1 alarm OBs | 3 | |
● Number of isochronous mode OBs | 1 | |
● Number of technology synchronous alarm OBs | 2 | |
● Number of startup OBs | 100 | |
● Number of asynchronous error OBs | 4 | |
● Number of synchronous error OBs | 2 | |
● Number of diagnostic alarm OBs | 1 | |
Nesting depth | ||
● per priority class | 24; Up to 8 possible for F-blocks | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC counter | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
S7 times | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC timer | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
Data areas and their retentivity | ||
Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB | |
Flag | ||
● Size, max. | 16 kbyte | |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
Data blocks | ||
● Retentivity adjustable | Yes | |
● Retentivity preset | No | |
Local data | ||
● per priority class, max. | 64 kbyte; max. 16 KB per block | |
Address area | ||
Number of IO modules | 8 192; max. number of modules / submodules | |
I/O address area | ||
● Inputs | 32 kbyte; All inputs are in the process image | |
● Outputs | 32 kbyte; All outputs are in the process image | |
per integrated IO subsystem | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
per CM/CP | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
Subprocess images | ||
● Number of subprocess images, max. | 32 | |
Address space per module | ||
● Address space per module, max. | 288 byte; For input and output data respectively | |
Address space per station | ||
● Address space per station, max. | 2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules | |
Hardware configuration | ||
Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) | |
Number of DP masters | ||
● Via CM | 1 | |
Number of IO Controllers | ||
● integrated | 2 | |
● Via CM | 0 | |
Rack | ||
● Modules per rack, max. | 80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules | |
● Quantity of operable ET 200SP modules, max. | 64 | |
● Quantity of operable ET 200AL modules, max. | 16 | |
PtP CM | ||
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
Time of day | ||
Clock | ||
● Type | Hardware clock | |
● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
● Deviation per day, max. | 10 s; Typ.: 2 s | |
Operating hours counter | ||
● Number | 16 | |
Clock synchronization | ||
● supported | Yes | |
● to DP, master | Yes; Via CM DP module | |
● to DP, slave | Yes; Via CM DP module | |
● in AS, master | Yes | |
● in AS, slave | Yes | |
● on Ethernet via NTP | Yes | |
Interfaces | ||
Number of PROFINET interfaces | 2 | |
Number of PROFIBUS interfaces | 1; Via CM DP module | |
Optical interface | No | |
1. Interface | ||
Interface types | ||
● RJ 45 (Ethernet) | Yes; X1 P1 and X1 P2 via BusAdapter BA 2x RJ45 | |
● Number of ports | 2; via BusAdapter | |
● integrated switch | Yes | |
● BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12 | |
Protocols | ||
● IP protocol | Yes; IPv4 | |
● PROFINET IO Controller | Yes | |
● PROFINET IO Device | Yes | |
● SIMATIC communication | Yes | |
● Open IE communication | Yes; Optionally also encrypted | |
● Web server | Yes | |
● Media redundancy | Yes | |
PROFINET IO Controller | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | Yes | |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) | |
— IRT | Yes | |
— PROFIenergy | Yes; per user program | |
— Prioritized startup | Yes; Max. 32 PROFINET devices | |
— Number of connectable IO Devices, max. | 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
— Of which IO devices with IRT, max. | 64 | |
— Number of connectable IO Devices for RT, max. | 256 | |
— of which in line, max. | 256 | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
— Number of IO Devices per tool, max. | 8 | |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
Update time for IRT | ||
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive | |
— for send cycle of 500 µs | 500 µs to 8 ms | |
— for send cycle of 1 ms | 1 ms to 16 ms | |
— for send cycle of 2 ms | 2 ms to 32 ms | |
— for send cycle of 4 ms | 4 ms to 64 ms | |
— With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
Update time for RT | ||
— for send cycle of 250 µs | 250 µs to 128 ms | |
— for send cycle of 500 µs | 500 µs to 256 ms | |
— for send cycle of 1 ms | 1 ms to 512 ms | |
— for send cycle of 2 ms | 2 ms to 512 ms | |
— for send cycle of 4 ms | 4 ms to 512 ms | |
PROFINET IO Device | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | No | |
— IRT | Yes | |
— PROFIenergy | Yes; per user program | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 4 | |
— activation/deactivation of I-devices | Yes; per user program | |
— Asset management record | Yes; per user program | |
2. Interface | ||
Interface types | ||
● RJ 45 (Ethernet) | Yes; X2 | |
● Number of ports | 1 | |
● integrated switch | No | |
Protocols | ||
● IP protocol | Yes; IPv4 | |
● PROFINET IO Controller | Yes | |
● PROFINET IO Device | Yes | |
● SIMATIC communication | Yes | |
● Open IE communication | Yes; Optionally also encrypted | |
● Web server | Yes | |
● Media redundancy | No | |
PROFINET IO Controller | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | No | |
— Direct data exchange | No | |
— IRT | No | |
— PROFIenergy | Yes; per user program | |
— Prioritized startup | No | |
— Number of connectable IO Devices, max. | 32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
— Number of connectable IO Devices for RT, max. | 32 | |
— of which in line, max. | 32 | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
— Number of IO Devices per tool, max. | 8 | |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
Update time for RT | ||
— for send cycle of 1 ms | 1 ms to 512 ms | |
PROFINET IO Device | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | No | |
— IRT | No | |
— PROFIenergy | Yes; per user program | |
— Prioritized startup | No | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 4 | |
— activation/deactivation of I-devices | Yes; per user program | |
— Asset management record | Yes; per user program | |
3. Interface | ||
Interface types | ||
● RS 485 | Yes; Via CM DP module | |
● Number of ports | 1 | |
Protocols | ||
● PROFIBUS DP master | Yes | |
● PROFIBUS DP slave | Yes | |
● SIMATIC communication | Yes | |
PROFIBUS DP master | ||
● Number of connections, max. | 48; Of which 4 each reserved for ES and HMI | |
● Number of DP slaves, max. | 125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
Services | ||
— PG/OP communication | Yes | |
— Equidistance | No | |
— Isochronous mode | No | |
— Activation/deactivation of DP slaves | Yes |