Simatic Siemens PLC ET 200 IP65 Memory Card 6ES7513-2GL00-0AB0

Ask Latest Price
Video Channel
Brand Name :SIEMENS
Model Number :6ES7513-2GL00-0AB0
Certification :CE
Place of Origin :Germany
MOQ :1
Price :USD
Payment Terms :L/C, T/T
Supply Ability :100
Delivery Time :10-12Days
Packaging Details :15,10 x 15,40 x 4,60
Cpu Type :S7-1500
Number Of Analog Inputs :Up to 32
Integrated Motion Control :Yes
Number Of Technology Modules :Up to 32
Communication Interfaces :PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, OPC UA
Integrated Data Logging :Yes
Number Of Analog Outputs :Up to 32
Programming Languages :Ladder Logic, Function Block Diagram, Structured Control Language
Integrated Web Server :Yes
Integrated System Diagnostics :Yes
High Speed Counters :Up to 8
Number Of Digital Inputs :Up to 64
Number Of Digital Outputs :Up to 64
Integrated Safety Functions :Yes
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

SIEMENS 6ES7513-2GL00-0AB0 DEGREE OF PROTECTION: IP65/67, SIMATIC MEMORY CARD REQUIRED CONNECTION MODULE REQUIRED

Okay, got it. The details you provided are for the SIEMENS 6ES7513-2GL00-0AB0 SIMATIC S7-1500 CPU module:

Product Description:
- The 6ES7513-2GL00-0AB0 is a SIMATIC S7-1500 CPU module.
- It has a degree of protection of IP65/67, which means it is dust-tight and protected against the effects of temporary immersion in water.
- A SIMATIC memory card is required for program storage and additional functionality.
- A connection module is required for interfacing the CPU module.

Key Features:
- SIMATIC S7-1500 CPU module with specific processing capabilities.
- Rated with a high degree of protection, IP65/67, making it suitable for use in harsh environments.
- Requires a SIMATIC memory card for program storage, firmware updates, and other advanced features.
- Requires a connection module for interfacing and connecting the CPU module.

Degree of Protection:
- The 6ES7513-2GL00-0AB0 module has a degree of protection of IP65/67.
- IP65 means the module is dust-tight and protected against low-pressure water jets from any direction.
- IP67 means the module is protected against the effects of temporary immersion in water up to 1 meter in depth.
- This high level of protection makes the module suitable for use in industrial environments with high levels of dust and moisture.

SIMATIC Memory Card:
- The 6ES7513-2GL00-0AB0 module requires a SIMATIC memory card for program storage, firmware updates, and additional functionality.
- The memory card provides the necessary storage capacity and enables advanced features of the CPU module.

Connection Module:
- A connection module is required for interfacing and connecting the 6ES7513-2GL00-0AB0 CPU module.
- The connection module allows for the installation and wiring of the CPU module within the application.

Approvals and Certifications:
- As a SIMATIC S7-1500 CPU module, the 6ES7513-2GL00-0AB0 likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- IEC 61784-2 (PROFINET)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals (e.g., DNV GL, ABS, LR, etc.)
- Any other relevant industry-specific certifications and standards required for the intended application and geography.

Please let me know if I have accurately summarized the key details of the SIEMENS 6ES7513-2GL00-0AB0 SIMATIC S7-1500 CPU module, including the degree of protection, required memory card, and connection module.

General information
Product type designation CPU 1513pro F-2 PN
HW functional status FS01
Firmware version V2.8
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; Via X1, with minimum OB 6x cycle of 500 µs
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V16
Configuration control
via dataset Yes
Control elements
Mode selector switch 1
Supply voltage
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 0.31 A
Inrush current, max. 0.4 A; Rated value
I²t 0.001 A²·s
from supply voltage 1L+, max. 0.35 A
Power
Infeed power to the backplane bus 2.275 W
Power loss
Power loss, typ. 5.3 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 450 kbyte
● integrated (for data) 1.5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 40 ns
for word operations, typ. 48 ns
for fixed point arithmetic, typ. 64 ns
for floating point arithmetic, typ. 256 ns
CPU-blocks
Number of elements (total) 2 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max. 1.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 450 kbyte
FC
● Number range 0 ... 65 535
● Size, max. 450 kbyte
OB
● Size, max. 450 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 500 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 1
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 2 048; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Hardware configuration
Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of IO Controllers
● integrated 2
● Via CM 0
Rack
● Modules per rack, max. 16; Expansion width max. 1.2 m
● Number of lines, max. 1
Time of day
Clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes
Interfaces
Number of PROFINET interfaces 2
Number of PROFIBUS interfaces 0
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1 P3
● Number of ports 3; 2x M12 + 1x RJ45
● integrated switch Yes
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes; MRP Automanager according to IEC 62439-2 Edition 2.0
PROFINET IO Controller
Services
— PG/OP communication Yes
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT Yes
— PROFIenergy Yes
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
— for send cycle of 500 µs 500 µs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of "odd" send cycles Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs 250 µs to 128 ms
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes
— Isochronous mode No
— IRT Yes
— PROFIenergy Yes; per user program
— Prioritized startup No
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— Asset management record Yes; per user program
2. Interface
Interface types
● RJ 45 (Ethernet) No
● Number of ports 1; 1x M12
● integrated switch No
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy No
PROFINET IO Controller
Services
— PG/OP communication Yes
— Isochronous mode No
— Direct data exchange No
— IRT No
— PROFIenergy Yes
— Prioritized startup No
— Number of connectable IO Devices, max. 32; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max. 32
— of which in line, max. 32
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for RT
— for send cycle of 1 ms 1 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes
— Isochronous mode No
— IRT No
— PROFIenergy Yes; per user program
— Prioritized startup No
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— Asset management record Yes; per user program
Interface types
RJ 45 (Ethernet)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
● Industrial Ethernet status LED Yes
Protocols
PROFIsafe Yes
Number of connections
● Number of connections, max. 128; Via integrated interfaces of the CPU
● Number of connections reserved for ES/HMI/web 10
● Number of connections via integrated interfaces 128
● Number of S7 routing paths 16
Redundancy mode
Media redundancy
— MRP Yes; as MRP redundancy manager and/or MRP client
— MRPD Yes; Requirement: IRT
— Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max. 50
SIMATIC communication
● S7 routing Yes
● S7 communication, as server Yes
● S7 communication, as client Yes
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; Max. 5 multicast circuits
● DHCP No
● SNMP Yes
● DCP Yes
● LLDP Yes
Web server
● HTTP Yes; Standard and user pages
● HTTPS Yes; Standard and user pages
OPC UA
● Runtime license required Yes; "Small" license required
● OPC UA Client Yes
— Application authentication Yes
— Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication "anonymous" or by user name & password
— Number of connections, max. 4
— Number of nodes of the client interfaces, recommended max. 1 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. 300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max. 100
— Number of simultaneous calls of the client instructions for session management, per connection, max. 1
— Number of simultaneous calls of the client instructions for data access, per connection, max. 5
— Number of registerable nodes, max. 5 000
— Number of registerable method calls of OPC_UA_MethodCall, max. 100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max. 20
● OPC UA Server Yes; Data access (read, write, subscribe), method call, custom address space
— Application authentication Yes
— Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication "anonymous" or by user name & password
— Number of sessions, max. 32
— Number of accessible variables, max. 50 000
— Number of registerable nodes, max. 10 000
— Number of subscriptions per session, max. 20
— Sampling interval, min. 100 ms
— Publishing interval, min. 500 ms
— Number of server methods, max. 20
— Number of inputs/outputs per server method, max. 20
— Number of monitored items, recommended max. 1 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max. 10
— Number of nodes for user-defined server interfaces, max. 1 000

Simatic Siemens PLC ET 200 IP65 Memory Card 6ES7513-2GL00-0AB0